Compact valve meter “ECO” type
for installation on concealed valves
TWO in ONE / 0.1-90 °C

Ventilzähler Kompakt „WG‑ElectronicFlow” zur Montage auf Unterputzventile TWO in ONE
Compact “ECO” type – armature and measuring head
for modular radio, M-Bus and pulse systems

Measuring range R80-H / R40-V

TypePUCode
Number
MID flow-
rate Q3
Flowrate
Qn m³/h
Size
inch
Length
mm
Price €
/ pc
EAN-
code
ECO-VTZ10423332.51.5147,004029376423332
VTZ connecting piece10429011/2" 4024,004029376429013
VTZ connecting piece10429023/4" 4024,004029376429020
VTZ connecting piece10429031"4058,004029376429037
Extension for
connecting piece
10429042521,004029376429044
Flow convertor10429051/2"350,004029376429051
Flow convertor10429063/4" 350,004029376429068
Flow convertor1042907 1" 350,004029376429075

Separate fittings:

Armature including flap rosette and knob104210082,00 4029376421000
Measuring head 10361012.51.5169,004029376361016
Knob10450009,004029376450000
Flap rosette104500110,004029376450017
Adapter for VTZ-Armature compact incl. profiled Gasket1450028,004029376450024
Filter Adapter for VTZ-Measuring Head incl. O-Rings1450036,004029376450031
Brass shut-off valve upper piece including grid socket 3/4"103400719,004029376340042
  • Can be retrofitted for all standard radio systems from well-known manufacturers
  • Impulse system according to DIN 43864
  • M-Bus module according to 1434-3

All plastic parts that come into contact with drinking water have a test certificate in accordance with the guideline for the hygienic assessment of organic materials in contact with drinking water (KTW guideline) and the DVGW regulations (W270), which confirms the suitability of the materials from a microbiological point of view.

The entire range of brass water meters fulfils all the requirements of the new DVGW regulations for drinking water DIN 50930-6.

Chrome-plated/brass housing according to UBA. All the materials we use therefore fulfil the requirements of §17 of the Drinking Water Ordinance.

of the Drinking Water Ordinance.

  • As dry runner
  • Highest measuring accuracy Standard up to R 100/upon request R 160
  • Compliant with UBA guidelines
Replacement model – for retrofitting existing
VTZ measuring head compact to UP-KOAX model

Measuring range R80-H / R40-V

TypeVEBestell-NummerMID Q3Qn m³/hZollBaulänge
mm
Preis €
/ Stück
EAN-
Code
VTZ connection housing incl. Adapter and profiled gasket1032133M38x1.5on request4029376321331